Error Code F_DEF_SENSOR

Freezer defrost sensor reading error prevents defrost cycle monitoring

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: F-DEF Sensor Error

What This Means

Bad connector contact at CN20 pin 6 and 8; Open circuit in sensor (infinite resistance); Short circuit in sensor (zero resistance); Water infiltration or corrosion; Bimetal switch failure

What actually causes this:

The defrost sensor lost connection or failed, so defrost cycles cannot be properly monitored and controlled

First Thing to Check

Verify CN20 connector is fully seated and inspect for moisture

Parts Involved

F-DEF SensorMAIN PCB CN20 connector pins 6-8R223 resistor (IC01 MICOM #6)

How to Fix

  1. 1

    Check CN20 connector insertion

  2. 2

    Measure voltage between CN20 pins 6 and 8 (BLU and W/GRY)

  3. 3

    Measure resistance between same pins

  4. 4

    Verify against temperature table DATA1

  5. 5

    Check bimetal switch condition

Need more help with your Samsung RF28T5021SR?