Error Code DAMPER_HEATER_ERROR

Damper heater malfunction prevents condensation prevention

Moderate

Address soon - your appliance may not work properly

Also displayed as: Damper Heater Error

What This Means

Heater open circuit (infinity resistance, nominal ~135 ohms); Heater short circuit (0 ohms); Bad connector contact at CN40 pins 25 and 27; Wiring disconnection or corrosion; MICOM relay failure for damper heater control

What actually causes this:

The damper heater failed or disconnected, allowing condensation to form on refrigerator door edges

First Thing to Check

Measure the heater resistance between CN40 pins 25 and 27

Parts Involved

Fresh Food Damper HeaterMAIN PCB CN40 connector pins 25-27MICOM #91 relay control

How to Fix

  1. 1

    Check CN40 connector insertion at pins 25 (Brown) and 27 (Black)

  2. 2

    Measure heater resistance between CN40 pins 25-27: should be ~135 ohms ±7%

  3. 3

    Measure MICOM #91 output voltage on pin 25-27

  4. 4

    Check expected voltage: 3.5V-4.8V when heater active, 0V when off

  5. 5

    Verify damper door operation