Error Code COMPRESSOR_ERROR

Compressor not starting or running properly due to electrical or mechanical failure

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: Compressor Not Running

What This Means

5-minute startup delay after power ON (normal for protection); Compressor locked or mechanical jam; Bad connector contact at CN102; Inverter circuit failure (IGBT or control circuit); Wiring disconnection from MAIN PCB; DC 15V or AC 115V supply failure; Overload protection activation

What actually causes this:

The compressor motor cannot start due to power supply failure, electrical disconnection, or internal mechanical failure

First Thing to Check

Wait at least 10 minutes after power off; check power plug; verify AC power at outlet

Parts Involved

Compressor Motor (Inverter type)MAIN PCB CN102 connectorSMPS power supply (12V, 5V, 15V)Inverter control circuit on MAIN PCB

How to Fix

  1. 1

    Wait 10 minutes minimum after power OFF before restarting (7-minute minimum protects compressor)

  2. 2

    In forced operation mode, verify compressor activation

  3. 3

    Check DC 15V at ZD501

  4. 4

    Verify AC 115V at CN81

  5. 5

    Check compressor connector CN102 insertion

  6. 6

    Verify DC 5V at C1009

  7. 7

    Check F-Sensor reading and forced operation signal

Need more help with your Samsung RF28T5A01S9?