Error Code 11

Condenser fan motor failure or control signal loss

Moderate

Address soon - your appliance may not work properly

Also displayed as: Left - ⑤ LED ON

What This Means

Condenser fan motor not operating; Feedback signal line broken; Motor wiring missing or cut; Motor bearing failure

What actually causes this:

The condenser cooling fan has failed or its control signal is lost, preventing heat removal from the refrigerant, causing the compressor to overheat

First Thing to Check

Check voltage at MAIN PCB CN75 between #1 (GRAY) and #2 (SKY BLUE); should be 7-12V

Parts Involved

Condenser Fan MotorMAIN PCB CN75Condenser CoilFan Blade

How to Fix

  1. 1

    Check voltage between MAIN PCB CN75 #1 (GRAY) and #2 (SKY BLUE)

  2. 2

    Voltage should be 7V to 12V

  3. 3

    Verify motor shaft can rotate freely

  4. 4

    Check for debris blocking fan blades

  5. 5

    Test connector continuity

Need more help with your Samsung RS25J500DWW?