LG Dryers

Error Code E5

Steam pump error — pump AD value below threshold during diagnostic test mode

Moderate

Address soon - your appliance may not work properly

Also displayed as: E5

How to Fix

  1. 1

    Enter Diagnostic Test Mode: unit in standby, press POWER while pressing MORE TIME and LESS TIME simultaneously.

  2. 2

    Press START/PAUSE four times to reach the steam/pump test step.

  3. 3

    Observe the AD value on display: if above 10, pump is normal.

  4. 4

    If AD value is below 10 and E5 is displayed, verify the steam inlet valve connection (DC 12V valve, coil resistance 24Ω ±10%, limit current 550mA).

  5. 5

    Check water supply connection and water pressure (29-116 PSI required).

  6. 6

    Check harness and connector to the pump and DC valve.

  7. 7

    If connections are good, replace the steam pump or DC valve assembly.

This Error Applies To

LG DLEY1701VE Series Dryers

Service manual exact match: DLEY1701BEService manual exact match: DLGY1702VEService manual exact match: DLEY1701VEService manual exact match: DLGY1702WEService manual exact match: DLGY1902KEService manual exact match: DLEY1701WEService manual exact match: DLGY1702BE