Samsung Dishwashers2018–present

Error Code AC6

The motor controller board inside the dishwasher stopped responding

Moderate

Address soon - your appliance may not work properly

Also displayed as: No display, changes to pause

What This Means

Main PBA or Inverter PBA is out of order; Communication connection between Main PBA and Inverter PBA is not properly connected; Wire harness between Main PBA and Inverter PBA is damaged

What actually causes this:

The motor controller board lost connection or failed, preventing the wash pump from running

First Thing to Check

Turn off the dishwasher at the circuit breaker, wait 2 minutes, then turn it back on

Parts Involved

Main PBAInverter PBA

How to Fix

  1. 1

    1. Check connections between Main PBA and Inverter PBA — reconnect all connectors

  2. 2

    2. Check wire harness for damage between the two boards

  3. 3

    3. If connections are secure, replace Inverter PBA

  4. 4

    4. If error persists, replace Main PBA

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

This Error Applies To

Samsung DW80M9 Series Dishwashers (2018) (2018–present)

Service manual exact match: DW80M9960US/AAService manual exact match: DW80M9960UG/AAService manual exact match: DW80M9550US/ACService manual exact match: DW80M9550UG/AAService manual exact match: DW80M9990US/AAService manual exact match: DW80M9990UM/AA

Need more help with your Samsung dishwashers?