Samsung Refrigerators2021–present

Error Code 13

Humidity sensor is faulty or disconnected

Moderate

Address soon - your appliance may not work properly

Also displayed as: F and R LEDs blink (item 13)

What This Means

Disconnected humidity sensor connector; Failed humidity sensor (HTG3515CH or HTG3535CH); Damaged wiring; Failed MAIN PCB input circuit at IC01 MICOM pin 11

What actually causes this:

The sensor that measures humidity inside the fridge compartment has failed

First Thing to Check

Check that the humidity sensor connector at CN51 is firmly plugged into the MAIN PCB

Parts Involved

Humidity sensor (HTG3515CH/HTG3535CH)MAIN PCBCN51 connector

How to Fix

  1. 1

    Check voltage at CN51 pin 4 (FLAT_WHT) to CN51 pin 8 (FLAT_WHT); should be 3.5V to 1.0V

  2. 2

    Verify connector is fully inserted

  3. 3

    Measure resistance at CN51-4 to CN51-8; should read about 50 ohm with open sensor

  4. 4

    If MICOM pin 11 input is abnormal, check soldering or replace PCB

This Error Applies To

Samsung RF18A5101 Series Refrigerators (2021) (2021–present)

Service manual exact match: RF44A5002**Service manual exact match: RF49A5102**Service manual exact match: RF57A5232**Service manual exact match: RF20A5101**Service manual exact match: RF50A5202**Service manual exact match: RF57A5002**Service manual exact match: RF5GA5202**Service manual exact match: RF20A5102**+2 more