Samsung Refrigerators2017–present

Error Code 83

The compressor circuit is showing abnormal current

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: Error 83

What This Means

Open compressor wiring at CN102; Bad soldering at shunt resistor R1 on Inverter PCB; Compressor winding failure; Refrigeration cycle abnormality

What actually causes this:

Abnormal current in the compressor circuit — could be a failed compressor, a broken wire, or a bad solder joint on the inverter board.

First Thing to Check

Power off and inspect the wiring to the compressor for any obvious damage or disconnection.

Parts Involved

Inverter PCBCompressorShunt resistor R308 (0.09 ohm)

How to Fix

  1. 1

    Check compressor connection at CN102

  2. 2

    Check resistance of R308 on Inverter PCB — should be 0.09 ohm

  3. 3

    Inspect for bad solder joints on inverter board

  4. 4

    Check compressor windings and refrigeration cycle

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

This Error Applies To

Samsung RF23M85 Series Refrigerators (2017) (2017–present)

Service manual exact match: RF23M85*0**Service manual exact match: RF23M8590SG/AAService manual exact match: RF23M8570SG/AAService manual exact match: RF23M8590SR/AAService manual exact match: RF23M8570SR/AA