Error Code 10
Compressor power control IC fault or compressor winding fault detected
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 82 (RR39/RR14/RZ32/RZ11/RQ32)
What This Means
IPM chip failure; Compressor winding short or open; Inverter PCB solder joint failure; Control signal circuit fault; Component short circuit on inverter board
What actually causes this:
The inverter board that controls the compressor motor has failed, or the compressor motor itself has an internal electrical short
First Thing to Check
Check if the inverter board is mounted properly and has no visible burned areas or blown components
Parts Involved
How to Fix
- 1
Inspect inverter PCB solder quality
- 2
Check for component damage on inverter board
- 3
Verify IPM supply voltage
- 4
Test compressor motor winding resistance
This Error Applies To
Samsung RR39T74 Series Refrigerators
Related Error Codes
Room temperature sensor circuit failure detected
Exterior room temperature sensor circuit failure
Freezer defrost heater approaching shutdown failure within 5 minutes
Compressor motor drawing excessive current indicating short or mechanical jam
Inverter power module temperature exceeded safe limit and shut down
Defrost cycle temperature sensor circuit failure
Freezer defrost heater circuit malfunction or stuck heater
AC mains voltage is too high, exceeding safe operating range