Error Code 2
Defrost cycle temperature sensor circuit failure
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 5 (RR39/RR14/RZ32/RZ11/RQ32)
What This Means
Slipped out sensor housing; Wire cut or short circuit; Temperature reading out of valid range; Defective sensor connection
What actually causes this:
The defrost sensor that monitors the evaporator coil temperature failed or became disconnected
First Thing to Check
Locate the defrost sensor near the freezer evaporator and verify the connector is fully seated
Parts Involved
How to Fix
- 1
Check voltage between MAIN PCB CN31 #7 AND #8 (should be 4.5V~1.0V)
- 2
Verify sensor housing position
- 3
Test continuity of sensor wiring
This Error Applies To
Samsung RR39T74 Series Refrigerators
Related Error Codes
Room temperature sensor circuit failure detected
Exterior room temperature sensor circuit failure
Freezer defrost heater approaching shutdown failure within 5 minutes
Compressor motor drawing excessive current indicating short or mechanical jam
Inverter power module temperature exceeded safe limit and shut down
Freezer defrost heater circuit malfunction or stuck heater
Compressor power control IC fault or compressor winding fault detected
AC mains voltage is too high, exceeding safe operating range