Freezer defrost heater approaching shutdown failure within 5 minutes

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 35 (RR39/RR14/RZ32/RZ11/RQ32)

What This Means

Separation of defrost heater housing; Poor defrost heater contact; Wire cut or short circuit; Temperature fuse fault

What actually causes this:

The defrost heater is about to fail or its control circuit is failing as the defrost cycle nears completion

First Thing to Check

Monitor if the freezer temperature rises dramatically or water leaks from the defrost drain

Parts Involved

Defrost HeaterTemperature FuseHeater Connector

How to Fix

  1. 1

    Check defrost heater voltage output

  2. 2

    Test temperature fuse for continuity

  3. 3

    Inspect heater element connections

  4. 4

    Verify thermostat operation

This Error Applies To