Error Code 3
Exterior room temperature sensor circuit failure
Moderate
Address soon - your appliance may not work properly
Also displayed as: 6 (RR39/RR14/RZ32/RZ11/RQ32)
What This Means
Slipped out sensor housing; Wire cut or short; Sensor pickup temperature out of range; Poor connector contact
What actually causes this:
The room temperature sensor that helps adjust cooling based on ambient conditions failed or disconnected
First Thing to Check
Check that the exterior sensor wire is connected to the control board near the back of the refrigerator
Parts Involved
How to Fix
- 1
Check voltage between MAIN PCB CN31 #3 AND #4 (should be 4.5V~1.0V)
- 2
Verify exterior sensor housing is secure
- 3
Inspect wiring for visible damage
This Error Applies To
Samsung RR39T74 Series Refrigerators
Related Error Codes
Room temperature sensor circuit failure detected
Freezer defrost heater approaching shutdown failure within 5 minutes
Compressor motor drawing excessive current indicating short or mechanical jam
Inverter power module temperature exceeded safe limit and shut down
Defrost cycle temperature sensor circuit failure
Freezer defrost heater circuit malfunction or stuck heater
Compressor power control IC fault or compressor winding fault detected
AC mains voltage is too high, exceeding safe operating range