Error Code 82

The inverter's power module has faulted

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: Error 82

What This Means

Short between compressor U, V, W phases; IPM voltage drop below 13.5V; Short between IPM pins; Overtemperature in IPM

What actually causes this:

The electronic module that controls the compressor motor speed has failed or been damaged.

First Thing to Check

Unplug for 10 minutes and restart — if this error returns immediately, the inverter board or compressor needs professional service.

Parts Involved

Inverter PCB (IPM: FNB40560)Compressor

How to Fix

  1. 1

    Check for shorts between compressor terminals

  2. 2

    Check IPM supply voltage (must exceed 13.5V)

  3. 3

    Inspect IPM chip (FNB40560) for damage

  4. 4

    Check compressor and refrigeration cycle