Samsung Refrigerators2021–present

Error Code 44

Main board and inverter board have lost communication

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: F and R LEDs blink (item 44)

What This Means

Damaged or disconnected inverter communication cable; Failed MAIN PCB communication port; Failed Inverter PCB; Poor soldering

What actually causes this:

The control board can no longer communicate with the compressor's inverter module, which will cause the compressor to stop running

First Thing to Check

Check the cable connecting the main board to the inverter PCB in the machine compartment

Parts Involved

MAIN PCBInverter PCBCommunication cable

How to Fix

  1. 1

    Check cable between MAIN PCB and Inverter PCB

  2. 2

    Confirm cable is undamaged and fully seated

  3. 3

    Use oscilloscope to verify communication signal

  4. 4

    Replace MAIN PCB first if cable is good; then Inverter PCB

This Error Applies To

Samsung RF18A5101 Series Refrigerators (2021) (2021–present)

Service manual exact match: RF44A5002**Service manual exact match: RF49A5102**Service manual exact match: RF57A5232**Service manual exact match: RF20A5101**Service manual exact match: RF50A5202**Service manual exact match: RF57A5002**Service manual exact match: RF5GA5202**Service manual exact match: RF20A5102**+2 more