Samsung Refrigerators

Error Code 9

Compressor failed to start during cooling cycle initiation

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 81 (RR39/RR14/RZ32/RZ11/RQ32)

What This Means

Compressor mechanical failure; Inverter PCB solder joint failure; DC voltage output too low; Compressor electrical connection failure; Short circuit in inverter circuit

What actually causes this:

The compressor either received no power signal, received damaged power, or mechanically jammed and cannot turn on

First Thing to Check

Listen for any humming or clicking sound from the compressor when you first plug in the refrigerator

Parts Involved

CompressorInverter PBADC Power SupplyCompressor Capacitor

How to Fix

  1. 1

    Check DC 16V output (must be above 13.5V)

  2. 2

    Inspect inverter PCB solder joints

  3. 3

    Test compressor terminal continuity

  4. 4

    Verify compressor and cycle are normal

This Error Applies To

Samsung RR39T74 Series Refrigerators

Service manual exact match: RR39T74Service manual exact match: RR14T74Service manual exact match: RZ32A74Service manual exact match: RQ32T76Service manual exact match: RR39A76Service manual exact match: RZ32T77Service manual exact match: RZ11T74Service manual exact match: RR39T76+2 more