Error Code 4

Freezer defrost sensor has failed or lost connection

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: Error 4

What This Means

Defrost thermistor open or shorted; Connector CN31-3 or CN31-4 loose; Wiring damage near freezer evaporator; Ice formation damaging sensor leads

What actually causes this:

The sensor that stops the defrost heater when the evaporator is warm enough has failed, which can cause over-defrosting or ice buildup.

First Thing to Check

Inspect the sensor located on the freezer evaporator coil for ice damage or disconnected wire leads.

Parts Involved

F DEF thermistor (502AT)Main PCB CN31 connector

How to Fix

  1. 1

    Check voltage at MAIN PCB CN31-3 to CN31-4: should be between 1.0V and 4.5V

  2. 2

    Disconnect CN31 and measure resistance at pins 3 and 4

  3. 3

    At 77°F (25°C), normal resistance is 5.0 kΩ

  4. 4

    Check MICOM IC01 pin #6 voltage (R313 on PCB)